This page describes how to configure an HSI-88 feedback interface in Traintastic.
Supported connection types
The HSI-88 can only be connected to Traintastic using a direct serial cable connection, or using a USB-to-Serial adapter.
Connection settings
- Device – Path to the serial device (e.g.,
COM3on Windows or/dev/ttyUSB0on Linux).
HSI-88 settings
Feedback modules
- Modules left – Number of 16-port S88 feedback modules connected to the left connector.
- Modules middle – Number of 16-port S88 feedback modules connected to the middle connector.
- Modules right – Number of 16-port S88 feedback modules connected to the right connector.
Debugging
- Debug log RX/TX – Log all HSI-88 communication (hex) for debugging purposes.
Need help or having issues?
If you encounter problems while configuring the HSI-88, or if your setup behaves differently than expected, check the community forum. Sharing your configuration and findings helps others and improves Traintastic.