Digikeijs DR5033
The Digikeijs DR5033 is a smart LocoNet booster with basic diagnostic feedback and remote control support.
Supported diagnostics
- Load
- Temperature (reported but not functional)
Control capabilities
- Power district can be enabled/disabled using an accessory address
Requirements and notes
- The temperature value always reports zero, even though the booster exposes this field
- The load value remains zero until the track current reaches approximately 400–500 mA
- Status feedback is limited compared to newer smart boosters
Configuration
- Interface – The LocoNet interface used to communicate with the booster
- Address – Booster LNCV address (factory default: 1)
- Polling interval – Interval (in seconds) at which diagnostic data is requested (default: 5 seconds)
Warning
Using a very short polling interval increases traffic on the LocoNet bus and may negatively affect overall system performance. The default value is recommended unless faster updates are really needed.